Acces control usa poarta garaj intrare casa cartela tag card parola remote

Descriere

Vânzatorul este direct răspunzator pentru produsul afișat în această pagină.

Disponibilitate: Indisponibil - Vezi produse similare

Specificatii

  • Voltaj: DC 12V
  • Memorie: 250 utilizatori
  • Distanta citire card: 0-10 cm
  • RF type: EM card
  • Temperatura: -10~55 C
  • Umiditate: 0 to 95 %
  • Optiune sonerie
  • Door Open options (admin user selectable) : Card (Key Tag) & Password/ Card (Key Tag) Only/ Password Only
  • Dimensiuni: 12cmx12cmx2cm
  • Include 5 chei magnetice

 

RFID

Access Control System

 

User’s Manual

 

 

 

 

Please read this manual thoroughly before installation.                

 

  1. Brief Product Introduction:

This product is RFID access control system, which is currently one of the advanced  access systems. It uses the latest central process unit (CPU) and memory chip of large capacity. There will be of no information loss even in case of power failure. It takes the latest HOMMARD technology, with strong power of three ways to open door: open by card read, open by card read adding with password, and open by password.

The perfect security functions let the users feel much more safe, which include door state monitoring, alarm output, safety mode, anti dismantling, RFID card and password. While its functions of opening button, close notification, door bell, to be connected with NO. and NC. locks bring more operating easiness to the users.

This product provides access control mode, which is safe and fully automatic, it is an ideal device for business organizations, offices, factories, residences and communities.

 

  1. Technical Features

No.

Item

Specification

1

Power supply

DC: Voltage 12V±10%; current < 0.1A

2

Max load

Alarm output: 100mA   Electrolock output: 5A

3

Dimension

116mm×116mm×20mm

4

Weight

180g

5

Ambient temp.

-20℃—60℃

6

RH

20%—90%

7

Memory capacity

Information of 500 user card, and 500 passwords

8

Induction distance

5-15CM

9

Car type

EM or EM compatible card

 

三、Status Indications:

LED Indicators

Status

Red LED

Green LED

Normal state

Flash

 

Valid card

 

Light

Invalid card

Light

 

Open

 

Light

Key Press

Light

 

Program Mode

Light

Flash frequent

Set OK

Light

Light

Alarm

Flash

 

 

 

Buzzer

Status

Description

Buzz

Valid card

Two short beeps

BiBi

Invalid card

Long beep once

Bi——

Key Press

Short beep once

Bi

Input valid password

 Two short beeps

BiBi

Input wrong password

Long beep once

Bi——

Alarm state

Continuous long beeps

Bi—Bi—Bi—

 

  1. 4. Setup:
  2. Default value: Login password 9 9 9 9  ,User password   1 2 3 4
  3. Enter programming mode:

                        Press  *    Login password    #  enter programming mode.

  1. Function setup (should be in programming mode):

1). Modify login password.

Press   0     new password    #    confirm new password    #

Note: the new password should be any 4-8 figures.

2). Add user card.

Press  1    read card   Input code    #

Note: the code should be three figures from 001 to 500, which should not duplicate. The code must be input, otherwise the card will be invalid. If add more than one cards, read the second card directly after the first three-digit code is put in before pressing  # .

3). Delete user card (three ways):

  1. Press 2  0   0   0   0    #   to delete all user cards.
  2. Press 2  read card    #  to delete the corresponding card
  3. Press 2  input code    #  to delete lost card.

4) Set open mode:

Press  3    0    0    #  by valid card only.

Press  3    0    1    #  by valid card and password.

Press  3    0    2    #  by valid card or password.

Note: factory setting is valid card.

Since the initial password can not be used to open door, If set to valid card or password mode, password for use should be modified.

5). Set the length of open time:

Press  4     X   X    # .

Note: XX is from 00-99, unit is second, factory setting is 6 seconds.

6). Set the length of alarm time:

Press  5     X   X    # .

Note: XX is from 00-99, unit is minute, factory setting is 3 minutes.

7) Set door state monitoring mode:

Press  6     0   0    #  to disable this function.

Press  6     0   1    #  to enable this function.

Note: to enable door state monitoring, reed switches must be installed, when this function is enabled, the following two functions can also be enabled at the same time:

  1. If the user put in the correct password to open the door, then forget to close the door, the buzzer will give audible sound to note the user.
  2. If the door is opened illegally, the system will activate alarm signal output, at the same time, buzzer emits sound alarm.

8). Set safety mode:

Press  7    0   0    #  to disable this function.

Press  7    0   1    #  to read 10 invalid cards or valid cards, then enter 4 wrong passwords successively, the system is locked for 10 minutes.

Press   7    0   2    #  to read 10 invalid cards or valid cards, then enter 4 wrong passwords successively, the system activates alarm signal output.

Note: factory setting this function is disabled.

9) Save the settings and exit programming mode:

Press  *  .

Note: * should be pressed within 1 minute to save the setting when any of the above operation is completed.

 

  1. Modify user password (no need in programming mode): after pressing  *  to read user card, the green LED flashes, input user password  then press      #  to enter password modifying mode. Now input new password of 4 figures, press   #  and input the new password again, press   #  to save the setting.
  2. How to use:

1). In normal work mode, can be open by one valid card.

2). When valid card and password mode, can be open if the correct password is put in within 10 seconds after card swiping.

3). If the password of a card is forgotten, the information of this card in the system should be deleted first, then add this card to the system again to modify the password.

4). If program password is forgotten, you can use jumper switchRESETat the main board to restore factory setting. First, power off. Then set jumper switch toONposition. Power on. Shift the jumper switch back to OFFposition after three beeps of the buzzer, now the factory setting is restored.

 


Attachment: wiring diagram for installation

 

 

 

 

NOTE: 1. Power off before installation wiring, hot line work is forbidden!!

  1. Normally, electrolock is connected out from power controller.

 

 

 