contor trifazat Landys&Gyr Dialog
-
Produs:Nou, Fără garanție
-
Numar articol:172067209
-
Disponibilitate:Indisponibil
-
Preț:289,00 Lei
-
Anuntul a expirat la:02.01.2018, 20:43
-
Ai o nelamurire?
-
Vandut de:
-
Vinde si tu:Pune in vanzare un produs ca acesta
-
Optiuni:
Descriere
Vânzatorul este direct răspunzator pentru produsul afișat în această pagină.
Disponibilitate: Indisponibil - Vezi produse similare
Specificatii
Contor trifazat Landys&Gyr Dialog model ZFD405CT44. 0257 S2
No. 78991502
5A/50Hz tm= 15min
3x100V
clasa 1 imp/kWh 40000 imp/kWh Clasa 0.5 S
Voltage
Nominal Voltage Un x V3 3 100 , x
V
3
3 110 , x V
3
3 115 , x V
3
3 200 ,
x V
3
230
3
3 190K
Voltage Range
Measurement 70 – 115 % Un
Functional 65 – 130 % Un
Frequency
Nominal Frequency fn 50 or 60 Hz
(selectable)
tolerance 90 – 110 % fn
Range for primary values:
(50) 100-40’000 A
400 V – 1000 kV
Measuring Accuracy
Load Dependency Class 0.2S Active
1 % In, cos ϕ = 1 ± 0.28 %
5 % In – Imax, cos ϕ = 1 ± 0.14 %
2 % In, cos ϕ = 0.5 ± 0.40 %
10 % In – Imax, cos ϕ = 0.5 ± 0.24
%
Deviations between the individual
phases at 100 % In < 0.10 %
Losses < 1 %
Average values of delivered meters with load on
all
phases
5 % In – Imax, cos ϕ = 1, < 0.05
%
(measurement uncertainty +/- 0.03
%)
5 % In – Imax, cos ϕ = 0.5, < 0.08
%
(measurement uncertainty +/- 0.06
%)
© Landis+Gyr AG H 71 0200 0214 d en - ZMQ200 / ZFQ200 /
ZCQ200 - Technical Data
2 / 8
Additional Power Supply
Additional Power Supply
nominal voltage ranges Un 100 – 230 V
AC/DC
24 – 125 V AC/DC
functional range 70 – 115 % Un
frequency 50 or 60 Hz
max power consumption 6 VA
Operating Behaviour
Voltage Failure (Power Down)
block inputs and outputs immediate
transmitting contacts after 100 ms
standby operation after 0.5 s
data storage after a further 0.2 s
switch off after approx. 2.5 s
Voltage Restoration (Power Up) 3
phase
function standby after 1 – 3 s
detection of
energy direction + phase voltage after 1 – 3
s
Power Consumption
General
all values are typical values at x
V
3
3 100
maximum values 1.5 x typical values
all values are voltage dependant
Current Circuit (only for measurement) < 0.1
VA
1 A 0.004 VA
5 A 0.09 VA
Power supply connected to the voltage
circuits
voltage circuit without
transmitting module and (0.5 W) 0.9
VA
communication unit
additional power supply
with transmitting module (0.8 W) 1.4
VA
and communication unit
Power supply not connected to the voltage
circuits
voltage circuit 0.05 VA
additional power supply type 0.1 VA
additional power supply
without transmitting module 3 VA
and communication unit
additional power supply
with transmitting module 4.5 VA
and communication unit
Environmental Influences
Temperature Range according to IEC
62052-11
metrological -10 °C – 45 °C
operation -25 °C – 55 °C
storage and transportation
with battery -25 °C – 55 °C
storage and transportation
without battery -25 °C – 70 °C
Temperature Coefficient
range -10 °C – 45 °C
at cosϕ = 1 (5 % In to Imax) < ±75
ppm/K
at cosϕ = 0.5 (10 % In to Imax) < ±150
ppm/K
Relative Humidity according to IEC
62052-11
annual average < 75 %
for 30 days in year 95 %
on other days 85 %
with the exception of condensation and formation
of
ice
Vibration according to IEC 68-2-6
frequency 10 – 500 Hz
frequency < 60 Hz hconst = 0.375
mm
frequency > 60 Hz aconst = 5 g
velocity 1 octave/min
duration 10 cycles
Half-wave sinusoidal shock according to IEC
68-2-27
Three shocks in six directions
amax 80 g
ti 11 ms
Impermeability according to IEC
60529
F6 and F9 housing IP51
Flammability according to IEC
695-2-1
(f6 housing only)
contact force of heating wire 1 N
duration 30 s
test temperature = 960°C (terminal
block)
test temperature = 650°C (housing)
Electromagnetic Compatibility
Electrostatic Discharges according to IEC
61000-4-2
contact discharge 8 kV
Immunity to Electromagnetic RF
Fields
according to IEC 61000-4-3
80 – 2000 MHz 10 V/m
measuring deviation < 1%
Radio Interference Suppression according
to
IEC/CISPR 22 class B
Fast Transient Burst Test to IEC
61000-4-4
current and voltage circuits not under load 4
kV
H 71 0200 0214 d en - ZMQ200 / ZFQ200 / ZCQ200 -
Technical Data © Landis+Gyr AG
3 / 8
current and voltage circuits under load 2
kV
auxiliary circuits > 40 V 2 kV
Insulation Strength
Insulation Test (Security)
all circuits to earth 4 kV 50 Hz
measurement circuits against
all other circuits 4 kV 50 Hz
outputs against all other circuits 2 kV 50
Hz
tariff inputs against all other circuits 2 kV 50
Hz
Impulse Voltage (Surge)
surge 1.2 / 50μs - 8 / 20μs differential
mode
- current and voltage circuits 4 kV @ 2
Ω
- auxiliary circuits > 40 V 1 kV @ 42
Ω
surge 1.2 / 50μs - 8 / 20μs common
mode
- current and voltage circuits 4 kV @ 12Ω
9μF
Protection Class ll according to IEC
62052-11
Calendar Clock
Accuracy at 23 °C < 5 ppm
Backup Time (Power Reserve)
with supercap > 20 days
loading time for max backup time 300
h
with battery (optional) 10 years
battery type CR-P2
Display
Characteristics
type LCD liquid crystal display
digit size in value field 8 mm
number of positions in value field up to
8
digit size in index field 6 mm
number of positions in index field up to
8
Inputs and Outputs
Optical Test Output Active and Reactive
Energy
pulse width 40 ms
maximum pulse frequency 12 Hz
Control Inputs
control voltages
100 – 125 V AC/DC
200 – 230 V AC/DC
24 V DC
48 – 60 V DC
The control voltage range is set by jumpers in
the
hardware.
input current ≤ 3 mA
Transmitting Contacts
type solid state relay
max switching voltage 125 V AC/DC
min switching voltage 24 V DC
max continuous switching current 55 mA
AC/DC
min switching current 0.1 mA
electrical lifetime > 15 x 109 pole
changes
contact resistance ≤ 50 Ω
insulation between the contacts
and other current circuits 3.75 kV AC/1
min
insulation between contact groups 2 kV AC/1
min
pulse length r4 20, 40, 80 ms
Alarm Contacts
type monostable with switchover
contact
max switching voltage 250 V AC/DC
normal switching voltage 24 V DC
min switching voltage 5 V DC at min 10
mA
max switching current 100 mA AC/DC at 250
V
min switching current 5 mA DC
electrical lifetime 105 switching
operations
with ohmic load
insulation 4 kV AC/1 min
Communication Interfaces
Optical Interface for Automatic Meter
Reading
Standard IEC62056-21
status binary 1 IR LED off
status binary 0 IR LED on
max bit rate 9600 bps
transmission mode serial, half
duplex,
asynchronous start/stop
protocol dlms (IEC
62056-42/46/53/61/62)
RS485 Interface to Other Meters (Daisy
Chain)
standard ISO 8482
max current consumption
(with 1 transmitter and 8 receivers) 15
mA
max current per unit 0.8 mA – 1 mA
status binary 1 differential voltage < -0.2
V
status binary 0 differential voltage > -0.2
V
Max bus length bit rate no. of
meters
1200m 19.2 kbps 16 meters
550m 38.4 kbps 32 meters
250m 57.6 kbps 32 meters
insulation 4 kV AC
transmission mode serial,
bidirectional,
protocol dlms (IEC
62056-42/46/53/61/62)
connections 2-wire, not
exchangeable
(twisted pair shielded cable
No termination resistor is needed for the
described
line data. If required by the system, an external
load
of 1.2 kΩ can be used.