Termostat digital W3230 / 220V Controler regulator temperatura
-
Ramburs cu Garantia de Livrare
Curierul special îți livrează produsul pe care tu îl achiți la primire. Dacă produsul nu este ca în descriere, îți recuperezi banii, inclusiv taxele de transport.
- Online
Descriere
Raporteaza produsVânzatorul este direct răspunzator pentru produsul afișat în această pagină.
SKU: T6350K
Specificatii
Produsul este nou!
Specificații în limba engleză:
Power Supply: AC 110V-220V
Temperature Control Range:-55℃-120℃
Resolution Ratio: 0.1°C(-9.9-99.9); 1°C(other range)
Color of Displaying: red/blue
Measurement accuracy: ±0.1°C
Control accuracy: 0.1°C
Sensor: NTC10K Waterproof sensor
Output: Relay Contact Capacity 20A 12V / 10A 220V
Environmental requirements: -10-60°C , humidity 20%-85%RH
Dimension: 79mm *43mm*26mm
Cutting Size: 73mm*39mm
Sensor wire: 1 meter
Function description:
P0: refrigeration or heating mode
P1: return difference setting
P2: maximum temperature setting upper limit
P3: minimum temperature setting lower limit
P4: temperature correction
P5: delay start time (unit: minute)
Instructions:
Connect the power supply and equipment to supply power to the
controller. At this time, it is displayed as measuring temperature.
Press SET once, the display temperature will flash, press +- to set
the desired temperature (press +- to quickly raise and lower) After
finishing, press SET to confirm the return. At this time, the
controller automatically performs relay on/off according to the
setting! The output of the thermostat is a 20A relay, which
satisfies various high-power loads. When the control circuit is
connected, the thermostat can be powered. At this time, the display
shows the ambient temperature.
Indicator light, digital tube status description
Indicator light: Blinking indicates cooling or heating start delay,
always on indicates that the relay is closed
Digital tube: Display LL is the sensor open circuit, please follow
the instructions to connect the sensor; display HH is out of the
measurement range, the thermostat will forcibly open the relay;
display --- for high temperature alarm
Parameter function description
Press and hold SET for 5 seconds to enter the main menu settings,
press +- to switch P0...P6, long press SET or 10 seconds without
button action, the controller automatically confirms the
return.
P0 cooling and heating mode
Press and hold SET for 5 seconds to display P0, press SET once to
set the working mode, press +- to switch [H is heating mode] [C is
cooling mode] Press SET once to return, long press SET or 10
seconds without button action controller automatically confirm
carry out.
In the cooling mode: when the temperature measurement value ≥ the
temperature set point, the refrigeration relay is closed and the
refrigerator is started; when the temperature measurement value ≤
temperature set point - the return difference, the refrigeration
relay is turned off and the refrigerator is turned off.
In the heating mode: when the temperature measurement value ≤
temperature set point, the heating relay pulls in and the heater
starts; when the temperature measurement value ≥ temperature set
point + hysteresis, the heating relay is turned off and the heater
is turned off.
P1 hysteresis setting
Press and hold SET for 5 seconds to display P0, press +- to switch
to P1, press SET once to return the difference, press +- to set the
difference to 0.1-15, press SET once after completion, long press
SET or 10 seconds without button The motion controller
automatically confirms the completion.
In the cooling mode: when the temperature measurement value ≥ the
set value, the relay is closed, the refrigerator starts; when the
temperature measurement value ≤ the set value - the difference
value, the relay is turned off and the refrigerator is turned
off.
For example, if the environment is 30 °C, the set value is 25 °C,
and the hysteresis is set to 2 °C. After the power is turned on,
the relay closes the refrigerator to start. When the cooling
reaches 23 °C, the relay turns off the refrigerator and the
refrigerator is turned off. The open temperature starts to rise.
When it rises to the set value of 25 °C, the relay closes the
refrigerator again, so the repeated cycle control temperature is
not higher than 25 °C.
In the heating mode: when the temperature measurement value ≤ the
set value, the relay pulls in and the heater starts; when the
temperature measurement value ≥ the set value + the difference
value, the relay is turned off and the heater is turned off.
For example, if the environment is 10 °C, the set value is 25 °C,
and the hysteresis is set to 2 °C. After the power is turned on,
the relay closes the heater to start. When it is heated to 27 °C,
the relay turns off the heater and the heater is turned off. The on
temperature begins to decrease. When it drops to the set value of
25 °C, the relay closes the heater to start again, so the repeated
cycle control temperature is not lower than 25 °C.
P2 maximum temperature setting upper limit
In order to avoid the danger of setting the temperature too high
due to the misoperation of others, the thermostat has the highest
setting upper limit function, which limits the setting range of the
highest temperature set point controlled by the thermostat.
Press and hold SET for 5 seconds to display P0, press +- to switch
to P2, press SET once to set the upper limit, press +- to set the
highest settable temperature, the maximum value is 110, press SET
once after completion, press SET or 10 The second button is not
pressed and the controller automatically confirms the
completion.
For example: set to 60 temperature set point can only be set to 60
° C. If the temperature set point is to be expanded, the upper
limit set value needs to be adjusted first.
P3 lowest temperature setting lower limit
In order to avoid the ice blockage caused by the misoperation of
others, the temperature controller has the lowest setting upper and
lower limit functions, which limits the setting range of the lowest
temperature set point controlled by the thermostat.
Press and hold SET for 5 seconds to display P0, press +- to switch
to P3, press SET once to set the minimum lower limit, press +- to
set the lowest settable temperature, the lowest value is -50, press
SET once after completion, press SET or The controller
automatically confirms completion without a button action for 10
seconds.
For example: set to 2 temperature set point can only be set to 2 °C
minimum. If the temperature set point is to be expanded lower, the
lower limit set value needs to be adjusted first.
P4 temperature correction
When the measured temperature is deviated from the standard
temperature or due to special needs of the user's hardware, this
function can be used for correction. The corrected temperature =
temperature before correction + correction value The valid range is
-7.0~7.0.
Press and hold SET for 5 seconds to display P0, press +- to switch
to P4, press SET once to correct, press +- to set the correction
value, press SET once after completion, long press SET or 10
seconds without button action controller automatically confirms
completion .
For example, the normal display is 25 degrees; when the temperature
is corrected to 0, it displays 25 degrees; when the temperature is
corrected to 1.5, it shows 26.5 degrees; when the temperature is
corrected to -1.5, it shows 23.5.
P5 delay start time (unit: minute)
When the refrigerator or heater is working with a delay, the delay
function can be turned on to protect the life of the device.
Press and hold SET for 5 seconds to display P0, press +- to switch
to P5, press SET once to set the delay start time unit is minute,
press +- to set 0-10 minutes, press SET to return after completion,
long press SET or 10 seconds No button action controller
automatically confirms completion
In the cooling mode: the first time the power is turned on, if the
current temperature ≥ the set value, the refrigerator will not
start the cooling immediately, and it needs to run after the set
delay time.
In the heating mode: the first time the power is turned on, if the
current temperature ≤ the set value, the heater will not start
heating immediately, and it needs to run after the set delay
time.
The chiller starts immediately when the downtime between the two
starts of the chiller or heater is greater than the set value of
the delay start time.
When the stop interval between the two starts of the refrigerator
or heater is less than the set value of the delay start time, the
device can start after restarting the set delay time of the set
after the run. The delay time is calculated from the moment of
shutdown.
For example, the setting delay is 5 minutes in the cooling state,
the cooling device starts to delay after the power is turned on,
and the refrigerator is turned on after 5 minutes. When the
required temperature is reached, the refrigerator stops, and the
timing starts, when the next cooling start timing is completed.
Work, unfinished timing must wait for the end of the timer to work,
the LED indicator flashes during the delay.
When the delay start is set to 0, it is equal to the off delay
function.
How to save settings
If you want to save the set data, set P7 to ON when the temperature
is set and the power is off. In this case, the last setting will be
retained when the power is turned off.
Reset
Due to some human reasons, the internal setting of the thermostat
is confusing. It takes a lot of time to set the time. In this case,
you can use this function to restore the factory settings. In the
off state, press and hold the + and - buttons simultaneously. ,
then power on, all the above parameters are restored to the factory
settings.
Atenție!
Se expediază în toată țara prin curierat rapid fără limită de kilometri în sistem ramburs.
Dacă aveți nelămuriri sau întrebări vă rog nu ezitați să sunați sau să-mi scrieți.
Modalitati de livrare si plata
LIVRARE
In Ostrov
-
- Prin curier cu Garantia de Livrare - 18 Lei in max. 2 zile lucratoare
In Romania:
-
- Prin curier cu Garantia de Livrare - 18 Lei in max. 2 zile lucratoare
- Ridicare de la locker Miercuri, 8 Mai. - 13,09 Lei
PLATA
- - Ramburs cu Garantia de Livrare
Curierul special îți livrează produsul pe care tu îl achiți la primire. Dacă produsul nu este ca în descriere, îți recuperezi banii, inclusiv taxele de transport.
- - Online
Politica de retur
- - Produsul se poate returna in maxim 3 zile lucratoare
- - Metoda de retur: Ramburs contravaloare produs
- - Costul transportului va fi suportat de catre cumparator
- - Alte detalii: Retur acceptat in conditiile Garantiei de Livrare